Home > Products > UPS > Single Phase UPS > Rackmount Line InteractiveUPS
|
As Business becomes increasingly dependent on technology for even fundamental operations, the need for system availability is of paramount importance.
The Double Online series UPS is designed for those applications that need maximum protection in the 600VA - 5100VA range. With its high-frequency, line interactive online topology, providing non stop clean sine wave power, advanced communications and space-saving tower design.
The Line Interactive Online UPS series with pure sine wave technology is the ideal power solution for networks, web servers, telecommunications applications and other critical electronic equipment.
UPS Features |
• Line Interactive technology |
• Boost and buck AVR |
• 50/60Hz frequency auto sensing |
• Cold start function (DC power on) |
• Tel/Modem internet spike protection |
• Digital microprocessor controlled |
• Short circuit and overload protection |
• Load segmentation receptacles controllable |
• High efficiency mode selectable |
Battery Features |
• Battery Saver feature - UPS idle mode |
• Optional Extension battery packs |
• Hot swappable battery by user |
• Battery remain time display |
• Extended back up time with battery pack |
• Overload, online and battery status indication |
Communication |
• Schedule shutdown & reboot |
• RS-232 comms port with monitoring software |
• UPSMON plus software monitoring |
• Support USB communication |
• SNMP Card slot |
• History record of power failure events |
Voltage |
• On line output voltage selected |
• Wide input voltage range |
LCD & Other Settings |
• Multiple language LCD display |
• LCD display front panel |
• Control all functions vis LCD like bypass, diagnostic, manual settings, etc. |
• Power factor correction |
• Manual bypass setting |
• Free run mode setting |
• EMI/RFI noise filter |
In addition to its proven design, the Line Interactive Online UPS series offer an advanced battery management system and sophisticated communications to provide maximum system availability. The battery management system uses a three-stage charging technique that not only doubles the service life of batteries but optimises charging time.
The communications are flexible, allowing for local, network or remote monitoring and management. This includes the latest version of the UPSMON Software Suite, which provides power monitoring and shutdown software across 100s of servers for safe shutdown.
The Line Interactive UPS series delivers a best-in-class power solution for maximum system availability and peace of mind. That means your critical systems keep working.
Even when presented with the most severe power problems, the series output remains within a remarkable +/-5% of nominal voltage - critical system always receives steady and clean power. The Line Interactive UPS series will protect you from an array of power failures, power sags, power surges and much more.
Model with LCD & Temperature Port
|
||||
Model | 800 | 1250 | 1500 |
|
Input | Capacity (VA) |
800VA | 1250VA | 1500VA |
Capacity (W) | 480W | 750W | 900W | |
Voltage/Load |
+/-25% at line input, single phase |
|||
Frequency | 50/60 Hz Auto Sensing | |||
Output | Voltage (on battery) |
Pure sine wave at +/-5% of nominal, -10% of nominal |
||
Frequency (on battery) | 50/60 Hz +/-0.5% | |||
Voltage Regulation (AVR) |
AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal |
|||
Protection & Filtering | Spike Protection | 320 Jules, 2ms | ||
Unit Input |
Fuse for models from 600VA~1500VA, breaker for models above 1500VA |
|||
EMI/RFI filter |
10dB at 0.15MHz, 50 dB at 30MHz |
|||
Overload Protection | UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds | |||
Transfer Time |
2/4 milliseconds (typical), including detection time | |||
Short Circuit | UPS output cut off immediately or input fuse(or breaker) protection | |||
LCD Indicators |
Status |
Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault statuts, load |
||
Alarm |
Battery Back up |
Slow beeping sound (about 0.25Hz) | ||
Battery Low |
Rapid beeping sound (about 1.00Hz) |
|||
Overload | Continuous tone | |||
Interface |
RS232 | Detect battery low, Schedule UPS on/off, AC input/output power status display | ||
Dry Contact | Sends AC fail and battery low signals, and receives shutdown signal from computer |
|||
Battery |
Type | Hot swappable, sealed, maintenance-free lead acid, with 5 or 10 years design life | ||
DC Voltage V Battery |
12V/7AH |
24V/7AH | 24V/7AH | |
Recharge Time |
4 hours (90%) |
|||
Battery Protection | Automatic self-test & discharge protection, Replace battery indicator | |||
Back Up Time |
7 minutes |
7 minutes | 7 minutes |
|
Physical | Input lnlet | IEC 320 (240V) (NEMA 5-15 (120V) on request | ||
Receptacles | 4 IEC / AUS GPOs. Please specify |
|||
19" Dimmensions (mm) |
483 x 381 x 84 (2U) |
483 x 381 x 130 (3U) | ||
19” Rack Net Weight kg | 18.0 | 23.5 |
26.1 |
|
Environment | Ambient Operation |
3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg | ||
Audible Noise |
-20 - 50°C | |||
Altitude | 3,500 metres maximum | |||
Audible Noise (1m distance) |
<40dBA (1 meter from surface) |
<45dBA (1 meter from surface) |
||
Storage Condition |
15,000 meter max. elevation | |||
Conformance | Safety | UL, CE, C-Tick |
||
Warranty | 2 years |
Model with LCD & Temperature Port
|
||||
Model | 2000 | 3000 | 5100 |
|
Input | Capacity (VA) |
2000VA | 3000VA | 5100VA |
Capacity (W) | 1200W | 1800W | 3060W | |
Voltage/Load |
+/-25% at line input, single phase |
|||
Frequency | 50/60 Hz Auto Sensing | |||
Output | Voltage (on battery) |
Pure sine wave at +/-5% of nominal, -10% of nominal |
||
Frequency (on battery) | 50/60 Hz +/-0.5% | |||
Voltage Regulation (AVR) |
AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal |
|||
Protection & Filtering | Spike Protection | 320 Jules, 2ms | ||
Unit Input |
Fuse for models from 600VA~1500VA, breaker for models above 1500VA |
|||
EMI/RFI filter |
10dB at 0.15MHz, 50 dB at 30MHz |
|||
Overload Protection | UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds | |||
Transfer Time |
2/4 milliseconds (typical), including detection time | |||
Short Circuit | UPS output cut off immediately or input fuse(or breaker) protection | |||
LCD Indicators |
Status |
Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault statuts, load |
||
Alarm |
Battery Back up |
Slow beeping sound (about 0.25Hz) | ||
Battery Low |
Rapid beeping sound (about 1.00Hz) |
|||
Overload | Continuous tone | |||
Interface |
RS232 | Detect battery low, Schedule UPS on/off, AC input/output power status display | ||
Dry Contact | Sends AC fail and battery low signals, and receives shutdown signal from computer |
|||
Battery |
Type | Hot swappable, sealed, maintenance-free lead acid, with 5 or 10 years design life | ||
DC Voltage V Battery |
48V/7AH | 72V/17AH | ||
Recharge Time |
4 hours (90%) |
|||
Battery Protection | Automatic self-test & discharge protection, Replace battery indicator | |||
Back Up Time |
7 minutes |
7 minutes | 10 minutes |
|
Physical | Input lnlet | IEC 320 (240V) (NEMA 5-15 (120V) on request | ||
Receptacles | 4 IEC / AUS GPOs. Please specify |
|||
19" Dimmensions (mm) |
483 x 381 x 130 (3U) |
483 x 710 x 214 (5U) | ||
19” Rack Net Weight kg | 28.4 | 32.5 |
81.8 |
|
Environment | Ambient Operation |
3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg | ||
Audible Noise |
-20 - 50°C | |||
Altitude | 3,500 metres maximum | |||
Audible Noise (1m distance) |
<40dBA (1 meter from surface) |
<45dBA (1 meter from surface) |
||
Storage Condition |
15,000 meter max. elevation | |||
Conformance | Safety | UL, CE, C-Tick |
||
Warranty | 2 years |